Overview of fc504 4 rooftop access and obstructions 2014 fire code effective as of march 30 th 2014 buildings that are 100 feet or less in height and have a slope.
Fdny roof access requirements.
You need to send people down for emergency egress.
While the desire to stack containers is understandable in an urban environment enclosure design requirements including deflagration venting and purge systems and the need for firefighter access to each container make stacking more complicated than simply lifting them and placing them on top of each other.
Areas required to be set aside for setbacks or access pursuant to the new york city fire code the new york city.
Access variance plan review in accordance with the rooftop access and obstruction requirements set forth in the nyc fire code 2014 fc504 4 and fc512.
Such clear path shall afford reasonable access to bulkhead doors fire escapes access ladders cockloft vents skylights scuttles and shafts.
If there is a roof deck for assembly use there needs to be open stairs and elevators or you risk doj for ada.
The floors of greenhouses shall be constructed to be at least equal to the requirements for roof construction on table 601 for the construction class of the building on which it is located.
Membrane roof coverings dogs high bulkheads penthouse structures walk through bulkhead roof level skylights covered with substandard material high cornices making access from aerial ladder dangerous high free standing walls around perimeter of building increased difficulties caused by rain snow and ice.
A the front wall of the building and any walls accessible from the frontage space must have a 6 ft wide.
Such path shall comply with the following requirements.
Unless the egress plan includes some kind of roof access.
It does not supersede.
The roof access is generally for the firefighters.
Roof position requirements 6.
Adequate size and location of access openings to.
The fdny rooftop clearance requirements were not made mandatory for existing rooftops when published in july 1 2008.
For rooftops constructed pursuant to plans approved by dob or the fdny on.
Fire code requirements fdny will review modification applications to ensure adequate access to all rooftadequate access to all rooftop areas that fdny would op areas that fdny would need to access for firefighting operations.
Such clear path shall be accessible from each rooftop perimeter access landing required pursuant to fc504 4 3.
This bulletin is a guidance document intended to help provide a better understanding of the fire code requirements for rooftop access and obstructions.