The 6 10 m ferrocement hollow roof slab performed in bending in a ductile manner and had an ultimate load capacity is 7 33 kn including a self weight of 5 44 kn i e.
Ferrocement roofing channel.
This paper includes the construction process and compares construction cost of ferrocement roofing channel system with conventional roofing system.
It is easy to construct uses less cement and steel than a conventional rcc roof and is also cheaper during the installation process the roof channel.
Ferrocement channels roofing vs rcc slab my house is constructed 16 years ago in load bearing construction and it is in good condition.
The thickness of these elements is just 25 mm.
There will be no nuts and bolt arrangement as in the case of ac sheet metal frp roofs.
The cement is typically a very rich mix of cement and sand in a 3 1 ratio.
The ferrocement roof consists panels size 1 5mtrs x1 2mtrs.
Ferrocement channels n a ferrocement is a thin wall of reinforced cement where layers of continuous mesh are covered on both sides with mortar n ferrocement elements are durable versatile light and waterproof n a ferrocement channel fc is a longitudinal element of a curved section oftensemi cylindrical.
This is the reason why ferrocement roofing channels enable cost savings upto 40 and saves energy upto.
It is precastusing moulds n a ferrocement channel uses less cement and steel while.
Ferrocement or ferro cement is a system of construction using reinforced mortar or plaster lime or cement sand and water applied over an armature of metal mesh woven expanded metal or metal fibers and closely spaced thin steel rods such as rebar the metal commonly used is iron or some type of steel.
Ferrocement channel roof provides light weight roofing 60 reduction in dead weight as compare to rcc pre casting of roof leads to substantial reduction in construction time 20 saving in cost possible because of reduction in steel quantity and elimination of coarse aggregates and.
This roofing system is designed as a segmental element which is very easy to cast cure and then manually erect over the bearing walls.
I am thinking to construct 2 bed rooms and 1 toilet on first floor with rat trap bond walls and ferrocement roofing channels.
And when used.
Unlike ac sheet metal frp roof all the ferrocement panels are joined monolithically.
Approximately and ferrocement portal and purlins replacing ac sheets and structurals steel trusses and purlins.
The length of these channel units equals to the length of the room to be roofed.
The ferrocement channel section beam had a moment capacity of 19 5 kn m and an equivalent elastic modulus of rupture of 15 4 mpa.
Will it be structurally stable and strong enough as compared with english bond walls and rcc slab roof.